ambulance sale:
A | Technical specs of vehicle | Quantity |
| Dimensions and masses | |
| Wheelbase (mm):3750 | |
| Wheel tread (mm): 1740/ 1704 (front/rear) | |
| Minimum ground clearance (mm):195 | |
| Turning diameter(m):13.3 | |
| Overall dimensions (mm):5780×2000×2680 | |
| Dimension of Patient's compartment (mm):3200×1700×1830 | |
| Complete vehicle curb mass:(kg):2760 | |
| GVW (kg):3700 | |
| Number of crew: 7 persons | |
| Engine:DURATORQ4D225H | |
| Fuel type: diesel | |
| Fuel consumption:10L/100km | |
| Working manner: in-line ,4 cylinders, Turbocharged inter-cooled, high pressure common rail diesel engine | |
| Displacement (ml.):2198 | |
| Emission standard:GB17691-2005 China V, GB3847-2005 | |
| Maximum power:100kw | |
| Max. torque: 350N.m | |
| Gearbox:MT-82 6 speed, mechanical | |
| Chassis :JX6581TA-M5 | |
| Front overhang:933/1097 (mm) | |
| Brake: four wheels disc brake, power-assisted brake | |
| Max. speed (Km/h):145 | |
| Steering system: gear, rack power-assisted steering | |
| Tire:215/75R16LT | |
| Fuel tank capacity(L):70 | |
B | Standard configuration of vehicle | |
1 | Manual side mirror | |
2 | Power window | |
3 | CD player | |
4 | Hand-free Intercom system between driver's cab and Patient's compartment | |
5 | 3 seats in driver's cab | |
6 | Double open rear door | |
7 | Foot pedal in rear door | |
| Air conditioner and lighting system | |
1 | the original air conditioning is installed in driver's cab | 1 |
2 | the original air conditioning is installed in Patient's compartment | 1 |
3 | Exhaust system is installed on Patient's compartment roof | 1 |
2 | 2 illumination lights for right side and left side of vehicle outside | 4 |
3 | 1 illumination light rear side of vehicle outside | 1 |
4 | illumination light front side of vehicle outside | 1 |
5 | LED illumination light in Patient's compartment | 6 |
6 | spotlight lights inner roof of Patient's compartment | 1 |
7 | Ultraviolet radiation disinfector light | 1 |
| Central power supply distribution system | |
1 | Automatic charging system | 1 |
2 | 10m mobile cable | 1 |
3 | 12V outlets in Patient's compartment | 3 |
4 | 220V outlets in Patient's compartment | 3 |
5 | 230V/16A waterproof outside outlet with protection cover | 1 |
6 | 12V DC power-supply system | 1 |
7 | Intelligent inverted power supply system(12V -220V) | 1 |
8 | Multi-function control system | 1 |
| Emergency alarm system | |
1 | Control plate of siren and alarm lamp mounted in driver's cab | 1 |
2 | Adjustable volume alarm apparatus | 1 |
3 | 100W loud speaker | 1 |
4 | Blue Flashing alarm light bar mounted on the front roof of vehicle | 1 |
5 | blue flashing alarm lamps four sides of vehicle outside roof | 8 |
F | Patient's compartment | |
1. | Partition wall between driver's cab and Patient's compartment , a glass window in wall to make observation | |
2. | A foldable doctor seat (with safe belt) mounted to floor near to compartment wall | 1 |
3. | Long bench one piece (suitable for 3 people) with safe belts, mounted in right side of Patient's compartment | 1 |
4. | Scoop stretcher storage cabinet under bench bed | |
5. | Oxygen bottle in steel, 3 cubic meters (10L×2) ,mounted in left side of vehicle | 2 |
6. | Oxygen terminal (with oxygen interface and humidification bottle) | 2 |
7. | Oxygen reducing valve | 1 |
8. | composite material interior decoration in patient compartment | |
9. | Medicine cabinet one piece made of high polymer material, mounted in left side of Patient's compartment | |
10. | imported Interior medical floor, acid & alkali resistance, fire prevention, anti-skid, anti-static. | |
11. | perimeter embossing edge wrapping of Patient's compartment , dust-proof, anti-skidding, washable | |
12. | Multi-functional interior roof in Patient's compartment , with handrail, transfusion hanging bracket | 1 |
13. | Ventilation fan mounted in the interior roof of Patient's compartment | 1 |
14. | Medicine and equipments storage cabinet under partition wall | 1 |
15. | Strong blue or red reflective strip in waist of body | |
16. | Storage cabinet mounted in left front side of patient compartment | 1 |
17. | Medical equipment cabinet in left side of Patient's compartment | 1 |
18. | 220V outside power supply | 1 |
19. | Collision avoidance head restraint mounted in Patient's compartment | 2 |
20. | Mobile Self-lifting stretcher | 1 |
21. | Adjustable shovel Stretcher | 1 |
Standard Configuration
1) Anti-corrosion, anti-slip, anti-static medical floor: 1set
2) Alarm lamp and warning system: 1set
3) Heating system: 1set
4) Air conditioning system: 1set
5) Integrated interior decoration: 1set
6) Ventilation fan system: 1set
7) Multi-functional top
8) Partition wall (with transparent windows): 1set
9) Oxygen supply system: 1set (10LX2 oxygen bottle)
10) Inverter: 1set
11) Power socket: 1set
12) External power supply: 1set
13) Ultraviolet radiation disinfector system: 1set
14) Lighting system in patient room: 1set
15) Hands-free intercom system: 1set
16) Transfusion system: 1set
17) Medicine and instrument cabinet: 1set
18) Patient bench bed: 1set
19) Multi-functional operation panel: 1set
20) Doctor chair: 1set
21) Anti-Collision Head restrain: 1set
22) Automatic loading-and-unloading stretcher: 1set
23) Scalable scoop stretcher: 1set
24) Fire extinguisher: 1set
25) Waste can: 1set
26) Mobile cable: 1set
27) Outside marking: 1set
After-Sale Guarantee of Exported Special Vehicles
1)Warranty period: 2 years or 50000km (whichever comes first).
2) The Seller guarantees the availability of all spare parts required for maintenance or
repairs. Within the warranty period, the Buyer shall only be required to pay the actual cost
of the spare parts and reasonable travel expenses of the technician to provide the
necessary service on site (including air tickets, room and visa). After the warranty period,
the Buyer shall pay an extra service fee of USD100-USD200 per person per day since the
date of air tickets.
3) In the event that the quality of any spare parts of the Equipment is (in the Buyer’s
opinion) affected, the Seller will provide replacement parts at no cost to the Buyer.
4) The Seller will provide the production license for the Equipment and one set of User
Manual for the Equipment and Special Vehicle in English
5) According to the official order quantity and actual situation of importing country, we can
also build an after-sale service station in importing country to supply all maintenance or
repairs of our special vehicles. Landcom company will supply after-sale warranty in
accordance with the international conventions.
SPARE PARTS:
The Seller agrees to supply the Buyer a recommended spare parts list for the Equipment.
The Seller agrees for a minimum period of 5 years, to sell to the Buyer at prevailing
delivery and payment terms, all necessary spare parts required for maintenance of the
Equipment, at a mutually agreed consistently lowest price as the Seller can provide.
Further, the Seller agrees to use its best efforts to provide emergency spare parts within a
twenty-four hour period after receipt of an emergency order from the Buyer. The attached
spare-parts list will be delivered together with the Equipment.
TECHNICAL SUPPORTS :
The Seller agrees to provide technical and consulting support directly by the team in its
China factory through remote methods (including by phone and by mail) to assist the
operation, maintenance, troubleshooting and repair instruction etc. of the Equipment. The
Seller shall also provide field technical instruction and training to the Buyer upon the
Buyer’s request, and Buyer will bear all costs for the training or technical instruction or
repairs on site.